Skip to main content
Calkulon

How to Calculate Stormwater Runoff

What is Stormwater Runoff?

Stormwater runoff volume is calculated using rainfall and surface area characteristics. It's essential for drainage system design.

Formula

Use rational method: Q = C×I×A where C is runoff coefficient, I is rainfall intensity, A is area
Q
C×I×A where C is runoff coefficient — C×I×A where C is runoff coefficient
C
C value — Variable used in the calculation
I
I value — Variable used in the calculation
A
A value — Variable used in the calculation

Step-by-Step Guide

  1. 1Use rational method: Q = C×I×A where C is runoff coefficient, I is rainfall intensity, A is area
  2. 2C varies by surface: impervious (0.8-0.95), pervious (0.1-0.3)
  3. 3Results show peak flow for design storm

Worked Examples

Input
Area 10 ha, 60% impervious, rainfall 100 mm/hr
Result
Q ≈ 1.8 m³/s peak flow
For drainage system sizing

Common Mistakes to Avoid

  • Using wrong rainfall intensity for design frequency
  • Neglecting impervious surface increases from development

Frequently Asked Questions

Why use runoff coefficient?

Not all rain becomes runoff; some infiltrates soil. Coefficient captures this fraction.

What storm frequency should be designed for?

Typically 10-year storm for urban areas, 100-year for critical facilities, varies by code.

Ready to calculate? Try the free Stormwater Runoff Calculator

Try it yourself →

Settings