Pressure Drop Calculator helps contractors and tradespeople accurately size, spec, and estimate materials and systems.

Formel

ΔP = f × (L/D) × (ρV²/2) using Darcy-Weisbach

Trinn-for-trinn guide

  1. 1Determine friction factor, pipe length, diameter, and flow velocity
  2. 2Apply the formula using your project measurements
  3. 3Add required safety factors or waste allowances per code

Løste eksempler

Inndata
100 ft of 1 inch pipe, 5 fps, water
Resultat
ΔP ≈ 4.3 PSI per 100 feet

Vanlige feil å unngå

  • Not applying code-required safety factors or derating
  • Forgetting to account for waste and cut losses in material estimates