Pump Sizing Calculator helps contractors and tradespeople accurately size, spec, and estimate materials and systems.

Formel

Pump HP = (Flow GPM × Total Head ft) / (3960 × Pump Efficiency)

Trinn-for-trinn guide

  1. 1Calculate total head (static + friction + pressure), select pump curve
  2. 2Apply the formula using your project measurements
  3. 3Add required safety factors or waste allowances per code

Løste eksempler

Inndata
50 GPM, 100 ft total head, 70% efficiency
Resultat
HP = (50 × 100)/(3960 × 0.70) = 1.8 HP

Vanlige feil å unngå

  • Not applying code-required safety factors or derating
  • Forgetting to account for waste and cut losses in material estimates

Klar til å beregne? Prøv den gratis Pump Sizing-kalkulatoren

Prøv selv →