Skip to main content
Calkulon

learn.howToCalculate

learn.whatIsHeading

Pump power requirement is calculated from flow, head, and efficiency. Proper sizing prevents under-pumping and excessive energy waste.

Wzór

Calculate: P = (Q × H × ρ × g) / η
P
(GPM × Total Head) / (3960 × Efficiency) — (GPM × Total Head) / (3960 × Efficiency)
Q
Q value — Variable used in the calculation
H
H value — Variable used in the calculation

Przewodnik krok po kroku

  1. 1Calculate: P = (Q × H × ρ × g) / η
  2. 2Or: P = (GPM × Total Head) / (3960 × Efficiency)
  3. 3Account for motor losses beyond pump efficiency

Rozwiązane przykłady

Wejście
Q = 0.05 m³/s, H = 20 m, ρ = 1000 kg/m³, η = 0.75
Wynik
P ≈ 13 kW required
Select larger motor for margin

Częste błędy do unikania

  • Under-estimating system friction loss
  • Over-sizing pump (operates inefficiently at partial load)

Często zadawane pytania

Why does head matter more than volume?

Quadratic relationship with head; doubling head doubles power. Efficiency varies with duty point.

How do you select pump size?

Choose pump with duty point (Q, H) near best efficiency point for long equipment life.

Gotowy do obliczeń? Wypróbuj darmowy kalkulator Pump Power

Spróbuj sam →